| ZrO2-Based pH | Glass-Based pH | Platinum Redox | High-P, High-T CMAS Corrosion Probe | High Temperature & High Pressure pH, Reference & Platinum Electrodes | |
| High-Temperature and High-Pressure Pressure Balanced Ag/AgCl Reference Probes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
High-Temperature and High-Pressure Pressure Balanced
Ag/AgCl Reference Electrodes are divided into three types (A, B, and C) and two
designs (External Reference Electrode or Internal Reference Electrode).
Types A and B have a compression fitting and an insertion tube. Type A has an NPT fitting with a metal seal that will be locked to the insertion tube after first use (insertion depth one-time adjustable only). Type B has an NPT fitting with a soft seal that can be reposition on the insertion tube after each use (insertion depth fully adjustable). The NPT fittings for Types A and B are sold separately. Type C has a threaded fitting. If the NPT size is 1/4" or larger, a thin-walled protection tube may be provided . Type C is ultra compact and may be used in autoclaves that have smaller access ports (1/8"). But the insertion depth for Type C is fixed at factory (non adjustable). Type C is available for internal design only. External design: Reference material (Ag/AgCl) is away from heated location and maintained near ambient temperature so that the probe is more stable when used at T>200 oC. Internal design: Reference material (Ag/AgCl) is in heated location so that the probe has a better defined thermodynamic potential. Not recommended for long-term use at T>200 oC.
Specifications: Pressure: Ambient to 2000 psi (13 MPa) (higher pressure models are available). Temperature: -External design: 0oC (32oF) to 305oC (581oF) for continuous use. -Internal design: 0oC (32oF) to 200oC (392oF) for continuous use; 200oC (392oF) to 305oC (581oF) for short-term use Tube/Fitting Materials: 316L Stainless steel (standard); Ti and C-276 are available. Seals: QueonTM . Liquid Junction: Saturated (standard) or 0.1 m KCl. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
High Temperature and/or High Pressure Ag/AgCl Reference Probes Selection Guide |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
+ Higher pressure models are available. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Call: (210) 924-3101 | Fax: (210)696-1126 | Email: info@corrinstruments.com | ||
| copyright © 2003-2009, Corr Instruments, LLC, San Antonio, TX, USA, All rights reserved. | ||||
lo